AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]


id0740a2801700

1.  Connect battery positive voltage to airflow mode actuator terminal F (or G), and ground to terminal G (or F), and then verify that the airflow mode actuator operates as shown in the table.

ar8uuw00002211

•  Apply the external power supply.
•  If the operation condition is not normal, replace the airflow mode actuator.

Terminal

Airflow mode actuator operation

F

G

B+
Ground
DEFROSTER→VENT
Ground
B+
VENT→DEFROSTER

2.  Verify that the resistance between terminals A and E, and C and E matches the airflow mode actuator operation as shown in the graph.

ar8wzw00001140

•  If the operation condition and resistance are not normal, replace the airflow mode actuator.

3.  Install the air mix actuator with the lever position shown in the figure.

ar8wzw00001473