DTC B2477 [INSTRUMENT CLUSTER]


id0902e8802300

DTC B2477

•  Configuration error
DETECTION CONDITION
•  Configuration error
•  Malfunction in the instrument cluster internal circuit
POSSIBLE CAUSE
•  Instrument cluster malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
PERFORM INSTRUMENT CLUSTER CONFIGURATION
•  Perform instrument cluster configuration.
•  Is B2477 displayed?
Yes
Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION.)
No
Go to next step.
2
VERIFY TROUBLESHOOTING OF DTC B2477 COMPLETED
•  Clear DTC from memory.
•  Is B2477 displayed?
Yes
Go to applicable DTC inspection.
No
DTC troubleshooting completed.