POWER WINDOW MAIN SWITCH INSPECTION
id091200802000
Vehicles With Exterior Open/close Function
1. Measure the voltage at each terminal (except terminals K and M).
2. Connect the negative battery cable.
3. Inspect the power window main switch connector for continuity at terminals K and M.
4. If the system does not work normally even though the inspection items or related wiring harnesses do not have any malfunction,replace the power window main switch.
Terminal Voltage Table (Reference)
ar8wzw00001113
|
Terminal |
Signal name |
Connected to |
Measured condition |
Voltage (V)/Continuity |
Inspection item (s) |
---|---|---|---|---|---|
A
|
Close output
|
Power window motor
|
While door glass is opening
|
1.0 or less
|
Power window motor
|
While door glass is closing
|
B+
|
||||
B
|
Power cut
|
Power window subswitch
|
• Ignition switch at ON
• Power cut switch at off
|
0.25
|
• Related wiring harness
• Power window subswitch
|
Ignition switch at ACC or LOCK
|
1.0 or lass
|
||||
Power cut switch at on
|
1.0 or less
|
||||
C
|
Power supply
|
Power window motor
|
Ignition switch at ON
|
B+
|
Power window motor
|
E
|
Power supply
|
P.WWIND1 30 A fuse
|
Under any condition
|
B+
|
P.WWIND130 A fuse
|
H
|
Serial 1
|
Power window subswitch
|
• Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
• Inspect the wiring harness between power window main switch terminal H and power window subswitch terminal C for the following:
|
Power window subswitch
|
|
K
|
GND
|
Body ground
|
Under any condition:Inspect for continuity to ground
|
Continuity detected
|
GND
|
M
|
GND
|
Power window motor
|
Under any condition:Inspect for continuity to ground
|
Continuity detected
|
Power window motor
|
N
|
IG2
|
Ignition relay
|
Ignition switch at ON
|
B+
|
Ignition relay
|
Ignition switch at ACC or LOCK
|
1.0 or less
|
||||
O
|
Pulse 1
|
Power window motor
|
Door glass moving
|
Approx. 6
|
Power window motor
|
Door glass stopped
|
0 or B+
|
||||
P
|
Pulse 2
|
Power window motor
|
Door glass moving
|
Approx. 6
|
Power window motor
|
Door glass stopped
|
1.0 or less
|
||||
Q
|
Open output
|
Power window motor
|
While door glass is opening
|
B+
|
Power window motor
|
While door glass is closing
|
1.0 or less
|
||||
R
|
Serial 2
|
Keyless control module
|
• Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
• Inspect the wiring harness between power window main switch terminal R and keyless control module terminal 2T for the following:
|
Keyless control module
|
5. Turn the ignition switch to ON position, and verify the LED illuminates.
Vehicles Without Exterior Open/close Function
1. Measure the voltage at each terminal (except terminals K and M).
2. Connect the negative battery cable.
3. Inspect the power window main switch connector for continuity at terminals K and M.
4. If the system does not work normally even though the inspection items or related wiring harnesses do not have any malfunction,replace the power window main switch.
Terminal Voltage Table (Reference)
ar8uuw00002448
|
Terminal |
Signal name |
Connected to |
Measured condition |
Voltage (V)/Continuity |
Inspection item (s) |
---|---|---|---|---|---|
A
|
Close output
|
Power window motor
|
While door glass is opening
|
1.0 or less
|
Power window motor
|
While door glass is closing
|
B+
|
||||
B
|
Serial 1
|
Door switch
|
• Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
• Inspect the wiring harness between power window main switch terminal B and door switch terminal A for the following:
|
• Related wiring harness
• Door switch
|
|
C
|
Power supply
|
Power window motor
|
Ignition switch at ON
|
B+
|
Power window motor
|
E
|
Power supply
|
P.WWIND1 30 A fuse
|
Under any condition
|
B+
|
P.WWIND1 30 A fuse
|
H
|
Serial 2
|
Power window subswitch
|
• Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
• Inspect the wiring harness between power window main switch terminal H and power window subswitch terminal C for the following:
|
Power window subswitch
|
|
K
|
GND
|
Body ground
|
Under any condition:Inspect for continuity to ground
|
Continuity detected
|
GND
|
M
|
GND
|
Power window motor
|
Under any condition:Inspect for continuity to ground
|
Continuity detected
|
Power window motor
|
N
|
IG2
|
Ignition relay
|
Ignition switch at ON
|
B+
|
Ignition relay
|
Ignition switch at ACC or LOCK
|
1.0 or less
|
||||
O
|
Pulse 1
|
Power window motor
|
Door glass moving
|
Approx. 6
|
Power window motor
|
Door glass stopped
|
0 or B+
|
||||
P
|
Pulse 2
|
Power window motor
|
Door glass moving
|
Approx. 6
|
Power window motor
|
Door glass stopped
|
1.0 or less
|
||||
Q
|
Open output
|
Power window motor
|
While door glass is opening
|
B+
|
Power window motor
|
While door glass is closing
|
1.0 or less
|
||||
R
|
Serial 3
|
Power window subswitch
|
• Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
• Inspect the wiring harness between power window main switch terminal R and power window subswitch terminal J for the following:
|
Power window subswitch
|
5. Turn the ignition switch to ON position, and verify the LED illuminates.