INSTRUMENT CLUSTER SPECIFICATIONS


id092200101100

Item

Specification

Speedometer
Meter type
LCD
Input signal communication system
CAN system
Input signal source
DSC HU/CM
Rated voltage
(V)
DC 12
Tachometer
Meter type
Stepping motor type
Input signal communication system
CAN system
Input signal source
PCM
Rated voltage
(V)
DC 12
Fuel gauge
Meter type
Stepping motor type (Reset-to-zero type)
Input signal communication system
Conventional communication system
Input signal source
Fuel gauge sender unit
Rated voltage
(V)
DC 12
Water temperature gauge
Meter type
Stepping motor type (Medium range stabilized type)
Input signal communication system
CAN system
Input signal source
PCM
Rated voltage
(V)
DC 12
Odometer/Tripmeter
Display
LCD
Indication digits
Odometer: 6 digits, Tripmeter: 4 digits
Input signal communication system
CAN system
Input signal source
PCM
Rated voltage
(V)
DC 12
Warning alarms
Sound frequency
(Hz)
1,800—2,600
Output sound pressure level
(dB)
62.5—85.0
Lights-on reminder warning alarm
Sound frequency
(Hz)
1,900
Sound cycle
Key reminder warning alarm
Sound frequency
(Hz)
1,800
Sound cycle
Over-revolution warning alarm
Sound frequency
(Hz)
2,600
Sound cycle
Seat belt warning alarm
Sound frequency
(Hz)
1,800
Sound cycle
Oil level warning alarm
Sound frequency
(Hz)
2,000
Sound cycle