• With the elimination of the voltage regulator, generator control is carried out by the PCM. (See GENERATOR CONTROL OPERATION.) Exciting current in the field coil is increased or decreased by the duty signal from the PCM sent to the power transistor built into the generator.
1
|
Pulley
|
2
|
Front cover
|
3
|
Front bearing
|
4
|
Rotor
|
5
|
Rear bearing
|
6
|
Stator
|
7
|
Regulator component (built-in power transistor)
|
8
|
Rectifier
|
9
|
Rear cover
|
10
|
Terminal B component
|
• The generator warning light in the instrument cluster illuminates under the following conditions. (See DTC DETECTION LOGIC AND CONDITIONS.)
• The generator strap is adopted to improve the belt adjusting serviceability.