AIR FUEL RATIO (A/F) SENSOR, HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL OPERATION


id014000782200


Operation Conditions

•  The PCM operates the A/F sensor, HO2S when the following conditions are met.

Item

Activation condition

Drive signal

A/F sensor
•  After engine start
•  After the engine has started and a fixed period of time has elapsed (the elapsed time period after the engine starts is determined by ECT).
•  ECT is 5°C {41°F} or more.
•  Battery positive voltage is 9 V or more and less than 16 V.
•  MAF sensor is normal (no DTC is stored in PCM).
•  The PCM outputs a duty signal.
•  The element temperature is measured by the impedance of the A/F sensor and a duty ratio is determined.
HO2S
•  Starter is off
•  After engine start
•  After the engine has started and a fixed period of time has elapsed (the time period after the engine starts lenghtens if the ECT falls below 0°C {32°F}.
•  ECT is 10°C {50°F} or more.
•  Battery positive voltage is 9 V or more and less than 16 V.
•  Charging efficiency is the fixed value or less, or during fuel cut.
•  The PCM outputs a duty signal. However the duty signal is either 100% or 0%.