Diagnostic procedure
STEP
|
INSPECTION
|
ACTION
|
|
---|---|---|---|
1
|
INSPECT AIRFLOW MODE ACTUATOR
• Inspect airflow mode actuator. (See AIRFLOW MODE ACTUATOR INSPECTION.)
• Is it normal?
|
Yes
|
Go to next step
|
No
|
Repair or replace malfunctioning part in accordance with further inspection result. (See AIRFLOW MODE ACTUATOR INSPECTION.)
|
||
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN VENT MODE OR OTHER MODES
• Does air blow out when in VENT mode?
|
Yes
|
Go to Step 5.
|
No
|
Go to next step.
|
||
3
|
INSPECT VENT
• Is vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to next step.
|
||
4
|
VERIFY THAT DUCT IN DASHBOARD IS INSTALLED
• Is duct in dashboard properly installed?
|
Yes
|
Inspect duct for clogging, deformity and air leakage, then go to Step 9.
|
No
|
Install duct securely in the proper position, then go to Step 9.
|
||
5
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN HEAT MODE OR DEFROSTER MODE
• Does air blow out when in HEAT mode?
|
Yes
|
Go to next step.
|
No
|
Inspect vent for clogging, then go to Step 9.
|
||
6
|
INSPECT DEFROSTER MODE
• Does air blow out when in DEFROSTER mode?
|
Yes
|
Operation is normal. Recheck malfunction symptoms.
|
No
|
Go to next step.
|
||
7
|
INSPECT VENT
• Is vent clogged?
|
Yes
|
Remove obstruction, then go to Step 9.
|
No
|
Go to next step.
|
||
8
|
VERIFY THAT DEFROSTER DUCT IS INSTALLED
• Is defroster duct properly installed?
|
Yes
|
Inspect duct for clogging, deformity, and air leakage, then go to next step.
|
No
|
Install duct securely in proper position, then go to next step.
|
||
9
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Does air blow out?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|