1. Insert the SSTs in the turbine.
2. Tighten the center collar of the SSTs.
3. Using the SSTs, position the indicator button on the converter housing and set the dial at zero.
4. Pull up on the SSTs and observe the dial indicator reading.
5. If the end play exceeds specification, install a new torque converter.