• Solenoid reducing pressure (20) pushes on the solenoid reducing valve to the right, while spring force pushes to the left.
• When solenoid reducing pressure (20) increases, the solenoid reducing valve moves to the right until pressure is drained. This maintains a constant pressure to keep the spring force and line pressure (7) balanced. Solenoid reducing pressure becomes fixed.
.