VARIABLE VALVE TIMING ACTUATOR INSPECTION[L3]
id0110a4801200
1. Disconnect the negative battery cable.
2. Remove the ignition coils. (See IGNITION COIL REMOVAL/INSTALLATION[L3])
3. Remove the spark plugs. (See SPARK PLUG REMOVAL/INSTALLATION[L3].)
4. Disconnect the oil control valve connector.
5. Remove the ventilation hose.
6. Remove the cylinder head cover.
7. Confirm that notch of the rotor and bump of the cover at the variable valve timing actuator are aligned and fitted.
atraaw00002326
|
8. Install the cylinder head cover.
9. Install the ventilation hose.
10. Connect the oil control valve connector.
11. Install the spark plugs.
12. Install the ignition coils.