THERMOSTAT INSPECTION[AJ (3.0L Duratec)]


id0112a2801300

1.  Inspect the thermostat for the following.

Warning
•  During inspection, the thermostat and water are extremely hot and can cause severe burns. Do not touch the thermostat and water.
•  The valve should not open under normal temperature.
•  Opening temperature and valve lift
―  If there is a malfunction, replace the thermostat.
Thermostat initial-opening temperature
84—88 °C {184—190 °F}
Thermostat full-open temperature
99 °C {210 °F}
Thermostat full-open lift
More than 7.3 mm {0.29 in}