VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION[L3]
id0113a2803100
1. Remove the air hose. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)
2. Disconnect the vacuum hose from the variable tumble shutter valve actuator.
atraaw00000586
|
3. Connect a vacuum pump to the variable tumble shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
Below –2.7 {–20, –0.7}
|
Starts to move
|
Above –33.4 {–251, –9.9}
|
Fully pulled
|