EGR VALVE INSPECTION[AJ (3.0L Duratec)]
id0116a1801100
Voltage Inspection
1. Connect the M-MDS.
2. Disconnect the vacuum hose from the EGR valve and plug the hose.
3. Install the vacuum pump to the EGR valve.
4. Start the engine and idle it.
5. Access the following PIDs using the M-MDS.
6. Gradually apply vacuum to the EGR valve using the vacuum pump and verify that the DPFEGR PID value is as indicated in the following table.
EGR valve characteristics standards
Vacuum applied to EGR valve |
DPFEGR PID value |
---|---|
Approx. 5.4 kPa
|
Starts increasing (EGR valve starts opening)
|
Gradually apply vacuum
|
Gradually increases
|
27—34 kPa
|
2.5 V or more
|
Keep applying 27—34 kPa for about 10 s
|
Constant voltage (Voltage does not lower within several seconds)
|