INPUT/TURBINE SPEED SENSOR REMOVAL/INSTALLATION[GF4AX-EL]


id051703801300

1.  Disconnect the negative battery cable.

2.  Remove the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)

3.  Disconnect the input/turbine speed sensor connector.

4.  Remove the input/turbine speed sensor.

atraaw00002001

5.  Apply ATF to a new O‐ring and install it on an input/turbine speed sensor.

6.  Install the input/turbine speed sensor.

Tightening torque
7.8—11.0 N·m {79—113 kgf·cm, 68.6—98.0 in·lbf}

7.  Connect the input/turbine speed sensor connector.

8.  Install the air cleaner component. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION[L3].)

9.  Connect the negative battery cable.