ON-BOARD DIAGNOSTIC FUNCTION


id070200100300


Sensor Check Function

•  Detects malfunctions in the evaporator temperature sensor, cabin temperature sensor, water temperature sensor, ambient temperature sensor, solar radiation sensor.
If a malfunction is detected, DTC displayed on LCD and display blinking.
•  If there is no malfunction, display lighting.

INSPECTION ITEM

DTC

LCD DISPLAY

NORMAL

MALFUNCTION

All sensor
S1.0
LIGHTING
BLINK
Evaporator temperature sensor
S1.1
LIGHTING
BLINK
Cabin temperature sensor
S1.2
LIGHTING
BLINK
Water temperature sensor
S1.3
LIGHTING
BLINK
Ambient temperature sensor
S1.4
LIGHTING
BLINK
Solar radiation sensor
S1.5
LIGHTING
BLINK


Actuator Operation Check Function

•  Detects malfunctions in the airflow mode actuator and the air mix actuator.
If a malfunction is detected, DTC displayed on LCD and display blinking. If there is no malfunction, the display lighting.

INSPECTION ITEM

DTC

LCD DISPLAY

NORMAL

MALFUNCTION

Airflow mode actuator and air mix actuator
S2.0
LIGHTING
BLINK
Air mix actuator (motor lock)
S2.1
LIGHTING
BLINK
Airflow mode actuator (motor lock)
S2.2
LIGHTING
BLINK
Air mix actuator (potentiometer)
S2.3
LIGHTING
BLINK
Airflow mode actuator (potentiometer)
S2.4
LIGHTING
BLINK


Fail-safe Function Table

INSPECTION ITEM

CONDITION

MEASURES

Cabin temperature sensor
Ambient temperature sensor
Nothing
•  The sensor limits the operational voltage from the climate control unit for approx. 18 s.
Airflow mode actuator (motor lock)
Detects a malfunction in the actuator operation angle for approx. 18 s after the actuator has been operated.
•  Stops the airflow mode actuator drive signal at the point a malfunction is determined
Air mix actuator (motor lock)
Detects a malfunction in the actuator operation angle for approx. 18 s after the actuator has been operated.
•  Stops the air mix actuator drive signal at the point a malfunction is determined
Airflow mode actuator (potentiometer)
below 0.06 V or 4.96 V or more
•  Stops the airflow mode actuator drive signal at the point a malfunction is determined
Air mix actuator (potentiometer)
below 0.06 V or 4.96 V or more
•  Stops the air mix actuator drive signal at the point a malfunction is determined
Cabin temperature sensor
below -40 °C {-40 °F}or 80 °C {176 °F} or more
•  Cabin temperature sensor input value is set at 25 °C {77 °F}
Ambient temperature sensor
below -40 °C {-40 °F}or 80 °C {176 °F} or more
•  Ambient temperature sensor input value is set at 20 °C {68 °F}
Evaporator temperature sensor
below -35 °C {-31 °F}or 60 °C {140 °F} or more
•  Turn off a magnet clutch
•  Evaporator temperature sensor input value is set at 4.12 V
Solar radiation sensor
4.12 V or more
•  Solar radiation sensor input value is set at 4.12 V
Water temperature sensor
below -30 °C {-22 °F}or 110 °C {230 °F} or more
•  Water temperature sensor input value is set at 80 °C {176 °F}