id070200810500
DTC S1.1 |
Evaporator temperature sensor |
---|---|
POSSIBLE CAUSE
|
• Evaporator temperature sensor malfunction
• Climate control unit malfunction
• Open or short circuit between evaporator temperature sensor and climate control unit
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Disconnect the climate control unit connector.
• Is resistance between terminals Z and AD of climate control unit connector as indicated below?
|
Yes
|
Replace climate control unit. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION.)
|
No
|
Go to the next step.
|
||
2
|
• Disconnect the evaporator temperature sensor connector.
• Is resistance between terminals A and B of evaporator temperature sensor connector as indicated below?
|
Yes
|
Repair wiring harness.
|
No
|
Replace evaporator temperature sensor. (See EVAPORATOR TEMPERATURE SENSOR REMOVAL/INSTALLATION.)
|
||
![]() |