DTC S2.1
id070200811100
DTC S2.1 |
Air mix actuator (motor lock) |
---|---|
POSSIBLE CAUSE
|
• Air mix actuator malfunction
• Heater unit (air mix link and/or air mix crank) malfunction
• Climate control unit malfunction
• Open or short circuit between air mix actuator and climate control unit
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Disconnect air mix actuator connector.
• Connect battery positive voltage to terminal A (or terminal F) and ground to terminal F (or terminal A) of air mix actuator connector.
• Does air mix actuator operate?
|
Yes
|
Connect air mix actuator connector, then go to Step 3.
|
No
|
Go to the next step.
|
||
2
|
• Remove air mix actuator.
• Operate air mix link by hand.
• Does air mix link operate smoothly?
|
Yes
|
Replace air mix actuator. (See AIR MIX ACTUATOR REMOVAL/INSTALLATION.)
|
No
|
Replace air mix link and/or air mix crank.
|
||
3
|
• Disconnect climate control unit connector.
• Connect battery positive voltage to terminal K (or terminal L) and ground to terminal L (or terminal K) of climate control unit connector.
• Does air mix actuator operate?
|
Yes
|
Replace climate control unit. (See CLIMATE CONTROL UNIT REMOVAL/INSTALLATION.)
|
No
|
Repair wiring harness.
|
||
![]() |