NO.2 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE
id070300800500
2
|
Amount of air blown from vents does not change.
|
DESCRIPTION
|
• Malfunction in blower system.
|
POSSIBLE CAUSE
|
• Blower relay, blower motor, resistor, fan switch malfunction
• Blower unit malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT BLOWER SYSTEM
• Inspect the following systems and electrical parts.
• Are they normal?
|
Yes
|
Go to next step.
|
No
|
Repair or replace malfunctioning part, then go to Step 5.
|
||
2
|
CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE
• Turn ignition switch to ON position.
• Turn fan switch on.
• Recirculate air inside vehicle.
• Does fan in blower unit rotate smoothly?
|
Yes
|
Go to Step 4.
|
No
|
Go to next step.
|
||
3
|
INSPECT BLOWER UNIT
• Inspect fan in blower unit.
• Is fan normal?
|
Yes
|
Go to next step.
|
No
|
Remove obstruction, repair or replace fan and blower unit case, then go to Step 5.
|
||
4
|
INSPECT BLOWER UNIT INTAKE VENT
• Is blower unit intake vent clogged?
|
Yes
|
Remove obstruction, then go to next step.
|
No
|
Inspect if there are any obstructions in passage between blower unit and A/C unit, then go to next step.
|
||
5
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Does air blow out?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|