AIRFLOW MODE ACTUATOR INSPECTION


id074000801700

Caution
•  If the lever position exceeds the operation range shown in the figure, the circuit in the actuator could be damaged. Always perform an actuator operation inspection with the lever movement within the range shown in the figure.

1.  Connect battery positive voltage to terminal A or F and ground to terminal F or A of the airflow mode actuator.

2.  Verify that the airflow mode actuator operates as shown below.

•  If there is any malfunction, replace the airflow mode actuator.

Connection

Movement

B+

GND

A
F
DEFROSTER → VENT
F
A
VENT → DEFROSTER

atraaw00003089
aesffw00000169

3.  Verify that the resistance between terminals B and E, B and C matches the airflow mode actuator operation as shown in the graph.

•  If there is any malfunction, replace the airflow mode actuator.
aesffw00000317