No.4 HAZARD WARNING LIGHT ILLUMINATED CONTINUOUSLY[TURN AND HAZARD WARNING LIGHTS]
id0902h1810300
Possible Cause
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT HAZARD WARNING SWITCH
Disconnect the hazard warning switch connector.
Do the hazard warning lights stop flashing?
|
Yes
|
Replace the hazard warning switch.
|
No
|
Go to the next step.
|
||
2
|
INSPECT RELATED WIRING HARNESS SHORT TO GROUND
Turn the ignition switch to the LOCK position.
Disconnect the flasher control module connector.
Measure the resistance between flasher control module terminal H and ground.
Is the resistance more than 10,000 ohms?
|
Yes
|
Replace the flasher control module.
|
No
|
Repair the related wiring harness.
|
||
![]() |