No.5 TURN LIGHTS (EITHER SIDE) DO NOT ILLUMINATE AT ALL[TURN AND HAZARD WARNING LIGHTS]
id0902h1810700
Possible Cause
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT INOPERATIVE LIGHT VOLTAGE
Turn the ignition switch to the LOCK position.
Disconnect the inoperative light connector.
Turn on the hazard warning lights.
Measure the inoperative light terminal voltage.
Is the voltage more than 10 V?
|
Yes
|
Go to the next step.
|
No
|
Repair the related wiring harness.
|
||
2
|
INSPECT INOPERATIVE LIGHT GROUND
Measure the resistance between the inoperative light and ground.
Is the resistance less than 5 ohms?
|
Yes
|
Replace the turn light socket.
|
No
|
Repair the related wiring harness.
|