DTC B2477[INSTRUMENT CLUSTER (L3)]


id0902h6802300

DTC B2477

Instrument cluster configuration error

Detection Condition
•  Malfunction in the configuration data
POSSIBLE CAUSE
•  The configuration operation was not performed correctly for some reason.

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
PERFORM CONFIGURATION
•  Perform instrument cluster configuration.
•  Is DTC B2477 indicated?
Yes
If the instrument cluster requires reconfiguration due to malfunction, replace the instrument cluster.
No
Go to the next step.
2
VERIFY THAT NO OTHER DTCS ARE PRESENT
•  Clear the DTC.
•  Turn the ignition switch to the LOCK position.
•  Turn the ignition switch to the ON position.
•  Is DTC B2477 present?
Yes
Go to the applicable DTC inspection.
No
DTC inspection completed.