No.4 INSTRUMENT CLUSTER DOES NOT RESPOND TO M-MDS[MULTIPLEX COMMUNICATION SYSTEM (AJ (3.0L Duratec))]
id0903g7819500
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT INSTRUMENT CLUSTER CONNECTOR
Turn the ignition switch off.
Disconnect the instrument cluster connector.
Inspect the instrument cluster connector for damage.
Is the instrument cluster connector normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the wiring harness. Perform the network test.
|
||
2
|
INSPECT FOR OPEN CIRCUIT BETWEEN DLC-2 AND INSTRUMENT CLUSTER
Inspect the resistance between the following instrument cluster terminals and DLC-2 terminals.
• Instrument cluster terminal 3E and DLC-2 terminal N
• Instrument cluster terminal 3C and DLC-2 terminal M
Is the resistance less than 5 ohms?
|
Yes
|
Go to the next step.
|
No
|
Replace the wiring harness. Perform the network test.
|
||
3
|
INSPECT INSTRUMENT CLUSTER OPERATION
Disconnect all the instrument cluster connectors.
Inspection:
• Corrosion
• Terminal separation
Connect all the instrument cluster connectors and verify that their positions are correct.
Operate the system and inspect for any malfunction.
Is any malfunction still present?
|
Yes
|
Replace the instrument cluster.
Perform the network test.
|
No
|
The system operates normally. The malfunction may result from loose connectors or corrosion. Clear the DTC. Repeat the self-test.
|