No.8 MODULE/NETWORK DOES NOT ESTABLISH COMMUNICATION - POWER IS NOT SUPPLIED TO M-MDS[MULTIPLEX COMMUNICATION SYSTEM (AJ (3.0L Duratec))]


id0903g7819900

STEP

INSPECTION

ACTION

1
INSPECT M-MDS
Inspect the M-MDS terminal for damage.
Is the terminal normal?
Yes
Go to the next step.
No
Repair the M-MDS connector. Inspect the system for normal operation.
2
INSPECT DLC-2 FOR DAMAGE
Turn the ignition switch off.
Inspect the DLS terminal for damage.
Is the terminal normal?
Yes
Go to the next step.
No
Repair or replace the DLC-2. Inspect the system for normal operation.
3
INSPECT M-MDS VOLTAGE
Measure the voltage at DLC-2 terminal D.
Is the voltage more than 10 V?
Yes
Go to the next step.
No
Repair the circuit. Inspect the system for normal operation.
4
INSPECT DLC-2 GROUND
Measure the resistance between DLC-2 terminals (H, J) and ground.
Is the resistance less than 5 ohms?
Yes
Repair the M-MDS. Inspect the system for normal operation.
No
Repair the malfunctioning circuit. Inspect the system for normal operation.