No.4 POWER IS NOT SUPPLIED IN START POSITION[POWER SUPPLY SYSTEM]


id0903g8820400

STEP

INSPECTION

ACTION

1
INSPECT IGNITION SWITCH
Inspect the ignition switch.
Is the ignition switch normal?
Yes
Repair or replace the related wiring harness.
Inspect the system for normal operation.
No
Replace the ignition switch. (See IGNITION SWITCH REMOVAL/INSTALLATION.)
Inspect the system for normal operation.