No.1 UNABLE TO COMMUNICATE WITH INSTRUMENT CLUSTER[INSTRUMENT CLUSTER (AJ (3.0L Duratec))]


id0903h0808400

STEP

INSPECTION

ACTION

1
INSPECT POWER SUPPLY TO INSTRUMENT CLUSTER
Turn the ignition switch off.
Disconnect the instrument cluster connector.
Turn the ignition switch to the ON position.
Measure the voltage at the following instrument cluster terminals (harness-side).
•  3K
•  1N
•  3O
Is the voltage more than 10 V?
Yes
Go to the next step.
No
Repair or replace the wiring harness. Inspect the system for normal operation.
2
INSPECT INSTRUMENT CLUSTER GROUND CIRCUIT
Turn the ignition switch off.
Measure the resistance between the following instrument cluster terminals (harness-side) and ground.
•  3I
•  3Q
Is the resistance less than 5 ohms?
Yes
No
Repair or replace the wiring harness. Inspect the system for normal operation.