No.17 MALFUNCTION INDICATOR LAMP (MIL) DOES NOT OPERATE[INSTRUMENT CLUSTER (AJ (3.0L Duratec))]


id0903h0854200

STEP

INSPECTION

ACTION

1
INSTRUMENT CLUSTER SIMULATION USING M-MDS
Turn the ignition switch off.
Connect the M-MDS to the DLC-2.
Turn the ignition switch to the ON position.
Select the ALL_LAMP in the simulation items.
Does the malfunction indicator lamp (MIL) illuminate?
Yes
Refer to powertrain control/emission diagnosis.
No
Go to the next step.
2
INSPECT INSTRUMENT CLUSTER OPERATION
Disconnect all the instrument cluster connectors.
Inspection:
•  Corrosion
•  Terminal separation
Connect the instrument cluster connector and verify that its position is correct.
Operate the system and inspect for any malfunction.
Is any malfunction still present?
Yes
Replace the instrument cluster. Inspect the system for normal operation.
No
The system operates normally. The malfunction may result from loose connectors or corrosion. Clear the DTC. Repeat the self-test.