No.17 MALFUNCTION INDICATOR LAMP (MIL) DOES NOT OPERATE[INSTRUMENT CLUSTER (AJ (3.0L Duratec))]
id0903h0854200
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSTRUMENT CLUSTER SIMULATION USING M-MDS
Turn the ignition switch off.
Connect the M-MDS to the DLC-2.
Turn the ignition switch to the ON position.
Select the ALL_LAMP in the simulation items.
Does the malfunction indicator lamp (MIL) illuminate?
|
Yes
|
Refer to powertrain control/emission diagnosis.
|
No
|
Go to the next step.
|
||
2
|
INSPECT INSTRUMENT CLUSTER OPERATION
Disconnect all the instrument cluster connectors.
Inspection:
• Corrosion
• Terminal separation
Connect the instrument cluster connector and verify that its position is correct.
Operate the system and inspect for any malfunction.
Is any malfunction still present?
|
Yes
|
Replace the instrument cluster. Inspect the system for normal operation.
|
No
|
The system operates normally. The malfunction may result from loose connectors or corrosion. Clear the DTC. Repeat the self-test.
|