INSTRUMENT CLUSTER CONFIGURATION


id092200800300

Note
•  The odometer data (total traveled distance) in the previous instrument cluster is automatically transferred to a new instrument cluster during the configuration.

1.  Connect the M-MDS to the DLC-2 (16-pin).

atraaw00001852

2.  After set up the M-MDS (including the vehicle recognition), the following can be selected from the M-MDS screen.

Using an IDS (Notebook PC):
•  "Module Programming"
Using a PDS (Pocket PC):
•  "Programming", "Module Programming"

3.  Select “Programmable Module Installation”.

4.  Select “IC” and perform procedures according to directions on the M-MDS screen.

5.  Retrieve DTCs using the M-MDS and verify that there is no DTC present.

•  If any DTC is present, perform applicable DTC inspection. (See DTC TABLE[INSTRUMENT CLUSTER (L3)].)(See DTC TABLE[INSTRUMENT CLUSTER (AJ (3.0L Duratec))].)