PID/DATA MONITOR AND RECORD PROCEDURE[L3]


id0922008006a6

1.  Connect the M-MDS or equivalent to the DLC-2 (16-pin).

atraaw00001950

2.  After the vehicle is identified, select the following items from the initialization screen of the M-MDS.

When using the IDS (notebook PC)
•  Select the “Toolbox” tab.
•  Select “DataLogger”.
•  Select “Module”.
•  Select “IC”.
When using the PDS (pocket PC)
•  Select “Module Tests”.
•  Select “IC”.
•  Select “DataLogger”.


Display Table

PID name

Input/output signal/Part name

Unit/Status

Terminal

ABS_MSG
ABS HU/CM circuit status
Present/Not Present
3C, 3E
CCNT_HE
Number of DTC
ECT_GAUGE
Engine coolant temperature gauge
°F
°C
3C, 3E
ODO COUNT
Odometer
m
mi (ft)
PCM_MSG
PCM circuit status
Present/Not Present
TACH
Tachometer
RPM
SPDOMETER
Speedometer
MPH
KPH