ELECTRICAL FAN CONTROL OPERATION [L3 R.H.D.]
BUE014000000N45
1
|
Control duty ratio
|
2
|
Coolant temperature
|
3
|
A/C switch ON
|
• When the engine coolant temperature is less than set value Tw1, the control duty ratio from by the PCM is 0%. Accordingly, the fan control module output duty ratio is also 0% and the cooling fan is stopped.
• When the engine coolant temperature passes Tw1, the control duty ratio from the PCM varies between LO-HI in relation to engine coolant temperature. and the cooling fan is driven accordingly.
• When the engine coolant temperature reaches set temperature Tw2, the duty ratio remains at HI until the engine coolant temperature is at set temperature Tw3.
• When the engine coolant temperature goes above Tw3, the duty ratio is MAX and the cooling fan operates at maximum speed.
A/C On And Refrigerant Pressure Control Signals
• When the A/C switch is ON and the refrigerant pressure rises above a set value, the control duty ratio from the PCM is approx. 100%, regardless of engine coolant temperature, and the cooling fan operates at maximum speed.
Fail Safe
• If the ECT sensor malfunctions, the PCM control duty ratio is fixed at MAX.
Battery Voltage Correction
• To prevent variation of cooling fan speed due to battery voltage fluctuation, the PCM adjusts the duty ratio to maintain the cooling fan at a constant speed and stabilize cooling efficiency.