DUTY CYCLE SOLENOID VALVE OPERATION [GF4AX-EL]
BUE051721101N05
On
The coil is energized, drawing the plunger upward to open the drain port and release hydraulic pressure.

|
1
|
Coil
|
|
2
|
Plunger
|
|
3
|
Released
|
Off
The plunger moves down due to spring force, closing the drain port to maintain hydraulic pressure.

|
1
|
Coil
|
|
2
|
Plunger
|
|
3
|
Pressure maintained
|
|
ATF Flow
|
Solenoid Valve
|
|
Released
|
On
|
|
Pressure maintained
|
Off
|
• The smaller the duty ratio (percent of on time during a fixed cycle), the higher the hydraulic pressure and, inversely, the larger the duty ratio, the lower the hydraulic pressure.