NO.1 MELTING OF MAIN OR OTHER FUSES [L3 R.H.D.]


id0103a4800700

1

MELTING OF MAIN OR OTHER FUSES

[TROUBLESHOOTING HINTS]

Inspect condition of fuse.

Damaged fuse

Related wiring harness

MAIN

Main fuse

• BTN2 fuse
• MAIN FAN1 fuse
• MAIN FAN2 fuse
• Generator
• IG MAIN fuse
BTN2

BTN2 fuse

• ROOM fuse
ROOM

ROOM fuse

• DLC
MAIN FAN1

MAIN FAN1fuse

• Cooling fan relay NO.2
- Cooling fan control module
MAIN FAN2

MAIN FAN2 fuse

• Cooling fan relay NO.1
- Cooling fan control module
IG MAIN

IG MAIN fuse

• Starter relay
- Starter
• IG KEY fuse
IGKEY

IG KEY fuse

• Ignition switch
FUEL

FUEL fuse

• Fuel pump relay
- Inertia fuel shutoff (IFS) switch
- PCM
INJ

INJ fuse

• Main relay
- HEGO fuse
- PCM
- Ignition coil
- Condenser
- Fuel pump relay
- Fuel injectors
- EGR valve
- VICS solenoid valve
- VTC solenoid valve
- Purge solenoid valve
- MAF sensor
HEGO

HEGO fuse

• O2 sensor
- PCM
ENG

ENG fuse

• EEC fuse
EEC

EEC fuse

• Main relay