CAMSHAFT POSITION (CMP) SENSOR INSPECTION [L3 R.H.D.]


id0140a7801400

Note
• Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. (See Troubleshooting Procedure.)

Resistance Inspection

1. Disconnect the CMP sensor connector.

2. Using a tester, measure the resistance between CMP sensor connector A-B terminals.

• If it is not within the specification, replace the CMP sensor.
• If the monitor item status/specification (reference) is not within the specification, even though the resistance is within the specification, perform the Circuit Open/Short Inspection, and repair or replace the malfunction part.
Standard
400-550 ohms [20 °C {68 °F}]