STEP
|
INSPECTION
|
ACTION
|
1
|
INSPECT COOLANT TEMPERATURE
• Is coolant sufficiently warmed up?
|
Yes
|
Go to next step.
|
No
|
Warm engine up, then go to Step 19.
|
2
|
CHECK CIRCUITS COMMON TO BOTH AIR MIX ACTUATOR AND AIRFLOW MODE ACTUATOR
• Does airflow mode change when operating airflow mode selector switch?
|
Yes
|
Go to Step 10.
|
No
|
Go to next step.
|
3
|
CHECK TO SEE WHETHER PROBLEM IS IN AIR MIX ACTUATOR +5 V SIGNAL OR POTENTIOMETER GND SIGNAL
• Is air mix actuator set at MAX HOT and airflow mode actuator at VENT?
(Verify position of air mix actuator link and airflow mode actuator link.)
|
Yes
|
Go to next step.
|
No
|
Go to Step 8. (Set actuator at MAX COLD and DEFROSTER.)
|
4*
|
CHECK TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Turn the ignition switch to ON position.
• Is there voltage of approx. 5 V at climate control unit connector (16-pin) terminal 1E (+5 V signal)?
|
Yes
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
No
|
Go to next step.
|
5*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN AIR MIX ACTUATOR (SHORT TO GROUND) OR ELSEWHERE
• Disconnect air mix actuator connector.
• Is there voltage of approx. 5 V at climate control unit connector (16-pin) terminal 1E (+5 V signal)?
|
Yes
|
Inspect air mix actuator, then go to Step 19.
|
No
|
Go to next step.
|
6*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN AIRFLOW MODE ACTUATOR (SHORT TO GROUND) OR ELSEWHERE
• Disconnect airflow actuator connector.
• Is there voltage of approx. 5 V at climate control unit connector (16-pin) terminal 1E (+5 V signal)?
|
Yes
|
Inspect airflow mode actuator, then go to Step 19.
|
No
|
Go to next step.
|
7*
|
CHECK TO SEE WHETHER MALFUNCTION (SHORT TO GROUND) IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)
• Disconnect climate control unit connector (16-pin).
• Is there continuity between climate control unit connector (16-pin) terminal 1E (+5 V signal) and ground?
|
Yes
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
No
|
Replace climate control unit, then go to Step 19.
|
8*
|
CHECK TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)
• Disconnect climate control unit connector (16-pin) and air mix actuator connector.
• Is there continuity between climate control unit connector (16-pin) terminal 1M (potentiometer GND signal) and air mix actuator connector terminal C?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
9*
|
CHECK TO SEE WHETHER MALFUNCTION (SHORT TO B+) IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)
• Turn the ignition switch to ON position.
• Test voltage at climate control unit connector (16-pin) and terminal 1M (potentiometer GND signal).
• Is voltage approx. 12 V?
|
Yes
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
No
|
Replace climate control unit, then go to Step 19.
|
10*
|
CHECK TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Turn the ignition switch to ON position.
• Test voltage at air mix actuator connector terminal E (+5 V signal).
• Is voltage approx. 5 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
11*
|
CHECK TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Turn the ignition switch to LOCK position.
• Disconnect climate control unit connector (16-pin) and air mix actuator connector.
• Is there continuity between climate control unit connector (16-pin) terminal 1R (potentiometer input signal) and air mix actuator connector terminal B?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
12*
|
CHECK TO SEE WHETHER MALFUNCTION (SHORT TO GROUND) IS IN WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Is there continuity between climate control unit connector (16-pin) terminal 1R (potentiometer input signal) and ground?
|
Yes
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
No
|
Go to next step.
|
13*
|
CHECK TO SEE WHETHER MALFUNCTION (SHORT TO B+) IS IN WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Turn the ignition switch to ON position.
• Test voltage at climate control unit connector (16-pin) terminal 1R (potentiometer input signal).
• Is voltage approx. 12 V?
|
Yes
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
No
|
Go to next step.
|
14*
|
CHECK TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE
• Turn the ignition switch to LOCK position.
• Is there continuity between following climate control unit connector (16-pin) terminals and air mix actuator connector terminals?
-
- Terminal 1M and terminal C (potentiometer GND signal)
-
- Terminal 1H and terminal F (motor drive signal)
-
- Terminal 1F and terminal A (motor drive signal)
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between climate control unit and air mix actuator, then go to Step 19.
|
15
|
INSPECT HEATER UNIT AIR MIX ACTUATOR LINK AND CRANK
• Is there grease on the link and crank?
|
Yes
|
Go to next step.
|
No
|
Apply grease, then go to Step 19.
|
16
|
INSPECT AIR MIX ACTUATOR
• Inspect air mix actuator.
• Is it normal?
|
Yes
|
Go to next step.
|
No
|
Replace air mix actuator, then go to Step 19.
|
17
|
VERIFY THAT HEATER UNIT AIR MIX DOORS DO NOT HAVE ANY FOREIGN MATERIAL OR OBSTRUCTION
• Is there any foreign material or obstructions on any heater unit door?
|
Yes
|
Remove material/obstruction, then go to Step 19.
|
No
|
Go to next step.
|
18
|
INSPECT HEATER UNIT AIR MIX DOORS
• Are all doors within heater unit securely and properly positioned?
• Inspect heater unit doors.
-
- Are doors cranked or damaged?
-
- Are doors securely and properly installed?
• Are they normal?
|
Yes
|
Replace climate control unit, then go to next step.
(Malfunction in climate control unit temperature control lever circuit)
|
No
|
Replace or install door(s) in proper position, then go to next step.
|
19
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Does temperature change when operating temperature control dial?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|