No.4 HAZARD WARNING LIGHT ILLUMINATED CONTINUOUSLY


id0902h1810300

Possible Cause

• Related wiring harness malfunction

• Hazard warning switch malfunction

• Flasher control module malfunction

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
INSPECT HAZARD WARNING SWITCH
Disconnect the hazard warning switch connector.
Do the hazard warning lights stop flashing?
Yes
Replace the hazard warning switch.
No
Go to the next step.
2
INSPECT RELATED WIRING HARNESS SHORT TO GROUND
Turn the ignition switch to the LOCK position.
Disconnect the flasher control module connector.
Measure the resistance between flasher control module terminal H and ground.
Is the resistance more than 10,000 ohms?
Yes
Replace the flasher control module.
No
Repair the related wiring harness.