2
|
INSPECT RELATED WIRING HARNESS SHORT TO GROUND
Turn the ignition switch to the LOCK position.
Disconnect the flasher control module connector.
Measure the resistance between flasher control module terminal H and ground.
Is the resistance more than 10,000 ohms?
|
Yes
|
Replace the flasher control module.
|