No.5 TURN LIGHTS (EITHER SIDE) DO NOT ILLUMINATE AT ALL


id0902h1810700

Possible Cause

• Turn light bulb malfunction

• Related wiring harness malfunction

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
INSPECT INOPERATIVE LIGHT VOLTAGE
Turn the ignition switch to the LOCK position.
Disconnect the inoperative light connector.
Turn on the hazard warning lights.
Measure the inoperative light terminal voltage.
Is the voltage more than 10 V?
Yes
Go to the next step.
No
Repair the related wiring harness.
2
INSPECT INOPERATIVE LIGHT GROUND
Measure the resistance between the inoperative light and ground.
Is the resistance less than 5 ohms?
Yes
Replace the turn light socket.
No
Repair the related wiring harness.