DTC B2477 [INSTRUMENT CLUSTER (L3)]


id0902h6840500

DTC B2477

Instrument cluster configuration error

Detection Condition

• Malfunction in the configuration data

POSSIBLE CAUSE

• The configuration operation was not performed correctly for some reason.

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
PERFORM CONFIGURATION
• Perform instrument cluster configuration.
• Is DTC B2477 indicated?
Yes
If the instrument cluster requires reconfiguration due to malfunction, replace the instrument cluster.
No
Go to the next step.
2
VERIFY THAT NO OTHER DTCS ARE PRESENT
• Clear the DTC.
• Turn the ignition switch to the LOCK position.
• Turn the ignition switch to the ON position.
• Is DTC B2477 present?
Yes
Go to the applicable DTC inspection.
No
DTC inspection completed.