1
|
INSPECT OTHER WARNING LIGHTS AND SECURITY LIGHT CIRCUIT IN INSTRUMENT CLUSTER
• Turn the ignition switch to the ON position.
• Do other warning lights and security light in the instrument cluster illuminate normally?
|
Yes
|
Turn the ignition switch to the LOCK position, then go to the next step.
|
2
|
CONNECT WDS OR EQUIVALENT AND PERFORM DTC INSPECTION
• Is DTC U1262 displayed?
|
Yes
|
Communication error between instrument cluster and PCM (SCP)
Inspect the wiring harness and connector between the instrument cluster and PCM.
• Malfunction in the wiring harness and connector.
-
- Repair or replace the wiring harness and connector, then go to the next step.
• Wiring harness and connector are normal.
-
- Repair or replace the instrument cluster.
|
3
|
Verify that the malfunction does not recur.
• Turn the ignition switch to the ON position.
• Does the security light operate correctly?
|
Yes
|
Troubleshooting completed.
|