No.1 CLIMATE CONTROL UNIT ILLUMINATION DOES NOT OPERATE


id0903c2815100

STEP

INSPECTION

ACTION

1
VERIFY ILLUMINATION OPERATION
Turn the light switch to the TNS position.
Do the instrument cluster, audio unit, rear window defroster switch, and hazard warning switch illuminate correctly?
Yes
Go to the next step.
No
Go to Step 4.
2
INSPECT ILLUMINATION POWER SUPPLY CIRCUIT
Disconnect the climate control unit connector.
Measure the voltage at climate control unit terminal 2G (harness-side).
Is the voltage 10 V or more?
Yes
Go to the next step.
No
Repair or replace the wiring harness. Inspect the system for normal operation.
3
INSPECT ILLUMINATION GROUND CIRCUIT
Measure the resistance between climate control unit terminal 2O (harness-side) and ground.
Is the resistance less than 5 ohms?
Yes
Replace the climate control unit. Inspect the system for normal operation.
No
Repair or replace the wiring harness. Inspect the system for normal operation.
4
INSPECT INSTRUMENT CLUSTER OPERATION
Inspect the instrument cluster connector.
Is the connector normal?
Yes
Operate the system and inspect for any malfunction. If any malfunction is still present, replace the instrument cluster. Inspect the system for normal operation.
No
Repair or replace the wiring harness. Inspect the system for normal operation.