2
|
INSPECT FOR OPEN CIRCUIT BETWEEN DLC-2 AND INSTRUMENT CLUSTER
Inspect the resistance between the following instrument cluster terminals and DLC-2 terminals.
• Instrument cluster terminal 3E and DLC-2 terminal N
• Instrument cluster terminal 3C and DLC-2 terminal M
Is the resistance less than 5 ohms?
|
Yes
|
Go to the next step.
|
3
|
INSPECT INSTRUMENT CLUSTER OPERATION
Disconnect all the instrument cluster connectors.
Inspection:
• Corrosion
• Terminal separation
Connect all the instrument cluster connectors and verify that their positions are correct.
Operate the system and inspect for any malfunction.
Is any malfunction still present?
|
Yes
|
Replace the instrument cluster.
Perform the network test.
|