No.2 HORN CONTINUES OPERATING


id0903c4819000

STEP

INSPECTION

ACTION

1
INSPECT HORN CIRCUIT
Turn the ignition switch off.
Remove the horn relay.
Does the horn continue operating?
Yes
Repair or replace the wiring harness. Inspect the system for normal operation.
No
Go to the next step.
2
INSPECT HORN RELAY
Inspect the horn relay.
Is the horn relay normal?
Yes
Install the horn relay, then go to the next step.
No
Replace the horn relay. Inspect the system for normal operation.
3
INSPECT HORN SWITCH CIRCUIT
Disconnect the clock spring connector.
Does the horn continue operating?
Yes
For vehicles with an immobilizer system, go to the next step.
For vehicles without an immobilizer system, repair the circuit.
Inspect the system for normal operation.
No
Go to Step 5.
4
INSPECT GEM INPUT
Disconnect the GEM connector.
Does the horn continue operating?
Yes
Repair or replace the wiring harness. Inspect the system for normal operation.
No
Refer to Section 09-14. Inspect the system for normal operation.
5
INSPECT HORN SWITCH
Disconnect the horn switch connector.
Measure the resistance between clock spring terminal A (harness-side) and ground under the following conditions.
• The horn switch is depressed: Less than 5 ohms
• The horn switch is not depressed: 10,000 ohms or more
Is the resistance normal?
Yes
Replace the clock spring.
No