Operation CHARM: Car repair manuals for everyone.

With Manufacturer's Scan Tool

CONSULT-II Function (ABS)





CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.

ECU (ABS/TCS CONTROL UNIT) PART NUMBER MODE
Ignore the ECU part number displayed in the ECU PART NUMBER screen. Refer to the parts catalog to order the ECU.

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carries out CAN communication.

SELF-DIAGNOSIS PROCEDURE
1. Turn ignition switch (OFF





2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Start engine.
4. Drive vehicle over 30 km/h (19 MPH) for at least one minute.





5. Stop vehicle with engine running and touch START (NISSAN BASED VHCL) on CONSULT-II screen.





6. Touch "ABS".





7. Touch "SELF-DIAG RESULTS".
- The screen shows the detected malfunction and how many times the ignition switch has been turned since the malfunction.
8. Make the necessary repairs following the diagnostic procedures.





9. After the malfunctions are repaired, erase the self-diagnostic results stored in the control unit by touching "ERASE".
10. Check ABS warning lamp for deactivation after driving vehicle over 30 km/h (19 MPH) for at least one minute.








SELF-DIAGNOSTIC RESULTS MODE

DATA MONITOR PROCEDURE
1. Turn ignition switch OFF.





2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Turn ignition switch ON.





4. Touch START (NISSAN BASED VHCL) on CONSULT-II screen.





5. Touch "ABS".





6. Touch "DATA MONITOR".
7. Touch "SETTING" on "SELECT MONITOR ITEM" screen.
8. Touch "AUTO TRIG" or "MANU TRIG" on "SET RECORDING CONDITION" screen.
9. Touch "START" on "SELECT MONITOR ITEM".








DATA MONITOR MODE

ACTIVE TEST PROCEDURE
- When conducting active test, vehicle must be stationary.
- When ABS warning lamp stays on, never conduct active test.

1. Turn ignition switch OFF.





2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Start engine.





4. Touch "START (NISSAN BASED VHCL)" on CONSULT-II screen.





5. Touch "ABS".





6. Touch "ACTIVE TEST".





7. Select active test item by touching screen.
8. Touch "START".
9. Carry out the active test by touching screen key.





ACTIVE TEST MODE

NOTE: Active test will automatically stop ten seconds after the test starts. (TEST IS STOPPED is displayed.)