Refrigerant Pressure Sensor / Switch: Service and Repair
Removal and Installation for Refrigerant Pressure SensorREMOVAL
1. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".
2. Disconnect the refrigerant pressure sensor harness connector and remove the refrigerant pressure sensor from the condenser.
CAUTION: Be careful not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
Refer to "Components". Exploded Views
CAUTION:
- Be careful not to damage the condenser fins.
- Replace the O-ring of the refrigerant pressure sensor with a new one, then apply compressor oil to it for installation.
- After charging refrigerant, check for leaks.