Fusible Link: Service and Repair
Replacing Fuse Element In Power Distributor
Technical values
Preliminary work
Disconnect battery ground strap.
Replacing fuse element
NOTE:
Voltage peaks
- Risk of damage to loads or to the control unit
- Disconnect the battery before removing the component or control unit.
WARNING:
Incorrect handling of safety bolts
- Danger of injury
- Loss of torque
- Always use new fastening screws and nuts following removal.
- Observe specified tightening torques.
- Carry out a visual inspection of all re-used parts.
1. Open the luggage compartment tray -arrow A- and remove the toolbox lying underneath -arrow B-.
2. Release the cover on the power distributor -a- and open it -arrow C-.
3. Unclip the HSB control unit at the clips -1- and set it aside together with the connections.
4. Unscrew the two hexagon nuts -2- from the blown fuse element and remove the fuse element.
5. Replace defective fuse element with a new fuse element.
6. Secure the fuse element with new fastening nuts -2-.
- Tightening torque: 5 Nm (3.5 ftlb.).
7. Clip the HSB control unit into the clips -1-.
8. Close the cover on the power distributor until it engages securely.
9. Insert the toolbox -arrow D- and close the luggage compartment tray -arrow E-.
Subsequent work
Connect battery ground strap.