DTC P0057 OXYGEN SENSOR HEATER CONTROL CIRCUIT LOW (BANK 2 SENSOR 2)CIRCUIT DESCRIPTION
DTC Detection Condition:
The heated oxygen sensor (HO2S) is used to monitor oxygen in the exhaust gas. For optimum catalyst operation, the air fuel mixture (air-fuel ratio) must be maintained near the ideal stoichiometric ratio. The HO2S output voltage changes suddenly in the vicinity of the stoichiometric ratio. The ECM adjusts the fuel injection time so that the air-fuel ratio is nearly stoichiometric.
The HO2S generates a voltage between 0.1 and 0.9 V in response to oxygen in the exhaust gas. If the oxygen in the exhaust gas increases, the air-fuel ratio becomes Lean. The ECM interprets the air-fuel ratio as Lean when the HO2S voltage is below 0.45 V. If the oxygen in the exhaust gas decreases, the air-fuel ratio becomes Rich. The ECM interprets the air-fuel ratio as Rich when the HO2S voltage is above 0.45 V.
HINT: The ECM provides a pulse width modulated control circuit to adjust current through the heater. The heated oxygen sensor heater circuit uses a relay on the B+ side of the circuit.
HINT:
- Bank 1 refers to the bank that includes cylinder No.1.
- Bank 2 refers to the bank that does not include cylinder No.1.
- Sensor 1 refers to the sensor closest to the engine assembly.
- Sensor 2 refers to the sensor farthest away from the engine assembly.
MONITOR DESCRIPTION
Monitor Strategy:
Typical Enabling Conditions:
Typical Malfunction Thresholds:
Component Operating Range:
The sensing portion of the heated oxygen sensor has a zirconia element that is used to detect oxygen concentration in the exhaust. If the zirconia element is at the proper temperature and the difference of the oxygen concentration between the inside and outside surface of the sensor is large, the zirconia element will generate voltage signals. In order to increase the oxygen concentration detecting capacity in the zirconia element, the ECM supplements the heat from the exhaust with heat from a heating element inside the sensor. When current in the sensor is out of the standard operating range, the ECM interprets this as a fault in the heated oxygen sensor and sets a DTC.
Example:
The ECM will set a high current DTC if the current in the sensor is more than 2 A when the heater is OFF.Similarly, the ECM will set a low current DTC if the current is less than 0.25 A when the heater is ON.
MONITOR RESULT
The test value and test limit information are described as shown in the table. Check the monitor result and test values after performing the monitor drive pattern.
- TID (Test Identification Data) is assigned to each emissions-related component.
- TLT (Test Limit Type):
If TLT is 0, the component is malfunctioning when the test value is higher than the test limit.
If TLT is 1, the component is malfunctioning when the test value is lower than the test limit.
- CID (Component Identification Data) is assigned to each test value.
- Unit Conversion is used to calculate the test value indicated on generic OBD II scan tools.
Wiring Diagram:
Step 1:
Step 1(Continued) - 3:
Step 4:
INSPECTION PROCEDURE
HINT:
- If different DTCs that are related to a different system are output simultaneously while terminal E2 is used as a ground terminal, terminal E2 may be open.
- Read freeze frame data using the hand-held tester or the OBD II scan tool, as freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, it is useful for determining whether the vehicle was running or stopped, the engine was warmed up or not, the air-fuel ratio was lean or rich, etc. at the time of the malfunction.