Hydraulic Test
HYDRAULIC TESTa. Measure the line pressure.
NOTE:
- Do the test at the normal operation fluid temperature the 50 to 80°C (122 to 176°F)
- The line pressure test should always be carried out in pairs. One technician should observe the conditions of wheels or wheel stoppers outside the vehicle while the other is doing the test.
- Be careful to prevent SST's hose from interfering with the exhaust pipe.
- This check must be conducted after checking and adjusting engine.
- Perform under condition that A/C is OFF.
- When conducting stall test, do not continue more than 10 seconds.
1. Warm up the ATF.
2. Lift the vehicle up.
3. Remove the engine under cover.
4. Connect hand-held tester to DLC3.
5. Remove the test plug A on the transaxle case front left side and install the SST.
SST 09992-00095 (09992-00231, 09992-00271)
NOTE: There is a difference in installation point between D position and R position.
6. Start the engine.
7. Using hand-held tester, shift to D position and hold 3rd by active test, and measure the line pressure in idling.
Specified line pressure:
8. Turn the ignition switch OFF.
9. Disconnect connector of transmission wire.
HINT: Disconnect the connector only when performing the D position stall test.
10. Start the engine.
11. Depress the brake pedal strongly, shift to D position, depress the accelerator pedal all the way down and check the line pressure in being stalled.
Specified line pressure:
12. Turn the ignition switch OFF.
13. Remove the SST, install the test plug A.
14. Remove the test plug B, install the SST and start engine.
SST 09992-00095 (09992-00231, 09992-00271)
15. Connect connector of transmission wire, depress the brake pedal strongly, shift to R position and check the line pressure in idling and being stalled.
Specified line pressure:
16. Remove the SST, install the test plug B.
17. Clear the DTC.
Evaluation: