S4 Continuity Check, Circuit 533 (T/R)
- Key OFF.
- Disconnect pump motor relay.
- Check continuity on Circuit 533 (T/R) to Pin 2.
- Is there continuity?
YES -- Go to S5. S5 Continuity Check, Pump Motor Relay to System Relay
NO -- Repair open in Circuit 533 (T/R). Go to S9. S9 Check For DTC Repeatability