Test K: The Hazard Lamps Are Inoperative
PINPOINT TEST K: THE HAZARD LAMPS ARE INOPERATIVENormal Operation
The smart junction box (SJB) provides voltage to the indicator flasher relay through circuit SPB17 (RD). The indicator flasher relay routes the voltage to the multifunction switch through circuit CLS32 (BN/YE). When the hazard switch is engaged, the multifunction switch routes the voltage to all the turn lamps.
This pinpoint test is intended to diagnose the following:
- Fuse
- Wiring, terminals or connectors
- Indicator flasher relay
- Multifunction switch
- SJB