Tightening Specifications
Connecting Rod Bolts
Inspection
Measure bolt diameter at Point A and Point B.
Calculate difference in diameter between Point A and Point B.
Point A-Point B 0-0.1 mm (0-0.004 in)
Install a new bolt if the difference in diameter is out of specification.
Tightening Sequence
First step 29 Nm (3.0 kg-m, 22 lb-ft)
Final step Tighten an additional 90°