Evaporative Check Valve: Testing and Inspection
Non-Return Valve A/B Inspection/Replacement
Special Tools Required
- Vacuum Pump/Gauge, 0-30 inHg Snap-on YA4000A or equivalent, commercially available
Inspection
1. Remove the non-return valve.
2. Connect a vacuum pump/gauge, 0-30 inHg, to the non-return valve as shown. Note the direction of the arrow on the valve.
3. Apply vacuum to the valve.
- If it holds vacuum, go to step 4.
- If it does not hold the vacuum, replace the non-return valve.
4. Connect the vacuum pump/gauge to the non-return valve as shown. Note the direction of the arrow on the valve.
5. Apply vacuum to the valve.
- If it holds vacuum, replace the non-return valve.
- If it does not hold the vacuum, the non-return valve is OK.
Non-Return Valve A Replacement
1. Remove the charge air cooler cover.
2. Disconnect the hoses, then remove non-return valve A.
3. Install the parts in the reverse order of removal.
NOTE: Make sure the arrow on the valve points in the correct direction.
Non-Return Valve B Replacement
1. Remove the air cleaner Service and Repair.
2. Remove the air bypass outlet pipe Service and Repair.
3. Disconnect the hoses, then remove non-return valve B.
4. Install the parts in the reverse order of the removal.
NOTE: Make sure the arrow on the valve points in the correct direction.